Biosafety Cabinet Class III

Fully airtight: the front window is closed, and the operation is fully airtight gloves. The sample is put into the operation room through the side phase inlet protected by the double door, without external valve

Description

Product Description

1. Fully airtight: the front window is closed, and the operation is fully airtight gloves. The sample is put into the operation room through the side phase inlet protected by the double door, without external valve;

2. Full discharge: 100% full discharge type, all gas does not participate in the circulation, and is directly discharged indoors after being filtered through two layers of filter membranes. If you need to discharge to the outdoors, you need to order an external discharge pipe cover, and be equipped with pipes and fans


Product Parameter

Model

Boka-1100lllx

External Size (W " D * H )

1540 *800 * 2000 mm

Internal Size (W " D * H )

910 * 650 * 660 mm

Pass Box Size (W " DH )

Internal Size : 430 *330 355mm

External Size : 575 * 425 495mm

Gloves

One pair of 800mm butyl rubber gloves

Front Window

8 mm toughened glass , anti-ultraviolet radiation

Display

LCD display

Pre-filter

Polyester fiber , washable

Pressure

≥ negative 120 Pa

ULPA Filter

Air supply filter: Efficiency 99.9995% at 0 . 12um

First exhaust filter: Efficiency 99.9995% at 0 . 12um

Second exhaust filter: Efficiency 99.9995% at 0 . 12um

Noise

NSF 49 61db / EN 12469s48db

Alarm

Audio and visual alarm, abnormal pressure; filter replacement

Work Zone

Material304 stainless steel

Illumination

21000LUX

Consumption

1200W

LED Lamp

12W *2

Gross Weight

350KG

Package Size (W " D * H )

1635*1062*2160mm

Standard Accessories

Gloves, fluorescent lamp, UV lamp " 4, remote control, pressure meter, drain valve


Product Detail

1. Humanized structure

The front window glass can be cleaned inside and outside

2. The retention rate of ULPA filter for solid particles larger than 0.12 bit meter diameter reaches 99995%

3. The gloves in the biological safety cabinet have undergone strict leak testing to ensure the protection of the operator.

4. The ergonomically inclined front angle of the cabinet improves the comfort for the operator.

5. The work area of the safety cabinet maintains negative pressure relative to the laboratory to prevent pollution factors from escaping from the work area.


Hot Tags: biosafety cabinet class iii, China biosafety cabinet class iii manufacturers, suppliers, factory, stainless steel pass box, cadaver lab tables, Stainless Steel Laboratory Furniture, Canopy fume hood, laminar chamber, science lab vent hood